Informe as condições de uso (temperatura, meios de contato, requisitos de desempenho etc.) e o sistema recomendará chapas/verguinhas de plástico de engenharia do catálogo por grau de compatibilidade. Não é necessário preencher tudo — 2 a 3 campos já geram recomendações úteis.
Valores são referências típicas; há variações entre lotes e normas de ensaio (ISO/ASTM). Para aplicações críticas, solicite a ficha técnica e valide em condições reais.
Engineering plastics selection works backwards from the operating conditions of a part - service temperature, contact media, flame rating, food contact and mechanical requirements - instead of scanning a grade data sheet and comparing candidates one by one. This tool normalises every POM, PA, PC, PEEK, PTFE, PVDF and PPS grade in the product catalogue onto the same dimensions, applies hard-constraint filtering first, then ranks the remaining candidates by the weights you set, and returns a list with a match score, cautions and a verification checklist.
It is meant for the concept stage: design engineers checking whether a material can work, process engineers assessing machining and assembly risk, and buyers checking grade availability and stock shapes. The output is a shortlist plus items to verify, not a substitute for prototyping and in-service testing.
Preencha os critérios ao lado e clique em "Buscar compatíveis" para ver os produtos recomendados por grau de compatibilidade.
The temperature the part sees continuously in service, not a short-term peak. Entering 120 means the material must withstand 120 deg C long-term. This is a hard threshold: grades rated below it are excluded or flagged. A common mistake is using heat deflection temperature (HDT) as the long-term limit - HDT is measured under a short-term load and is usually higher than the allowable continuous service temperature.
Brief excursions such as welding, drying or sterilisation. Exceeding it does not always exclude a material, but it appears in the cautions: dwell time and heating/cooling rate must then be controlled in the process.
The tool covers five media with reliable data: strong acids, strong bases, weak acids and bases, organic solvents, and hot water or steam. Ratings are resistant, borderline or not recommended. Oils and electrolytes have no standard rating - please ask us directly, as they require immersion testing at the actual concentration, temperature and contact time.
Select V-0 only when it is actually required. Flame-retardant grades usually trade some toughness and chemical resistance for cost. If the part sits near a heat source or the end product certification requires it, follow the assembly-level rating even when the part itself has no explicit requirement.
Filters the list to materials with an FDA or food-contact compliance statement. Compliance is a grade-level property, not a property of the material family, and it is tied to contact media, temperature and cleaning conditions.
A hard threshold: grades with lower room-temperature tensile strength are excluded. Tensile strength is temperature dependent, so for hot applications use the value at the target temperature rather than the room-temperature figure.
Leave at none and the dimension does not affect ranking; general corresponds to a weight of 0.6 and important to 1.0. Creep matters for bolted joints and parts under sustained load; dimensional stability mainly reflects moisture expansion, most pronounced in PA.
Shape (sheet, rod, turned sheet) only narrows the list to deliverable items and does not affect scoring. Colour can affect compliance documentation and appearance for some grades, but not mechanical performance.
Step one is hard-constraint filtering on continuous temperature, minimum tensile strength, contact media, flame rating and food contact. Any failed constraint excludes or flags a candidate. Dimensions with missing data are flagged rather than excluded, so that a sheet and a rod of the same material are not both dropped and leave an empty result.
Step two is weighted scoring. Each performance dimension is normalised to a 0 to 1 range using the minimum and maximum across the whole material pool, multiplied by the weight you selected, then divided by the sum of the weights. Because the normalisation baseline comes from the full pool rather than the current filtered set, scores for the same material remain comparable across different queries.
match score = sum(w x s) / sum(w)w: important = 1.0, general = 0.6, none = 0s: normalised dimension score, from 0 to 1Values come from published typical data for the grades in our catalogue, some measured under ISO or ASTM conditions. Batch variation and differences in test standards introduce deviation; for critical applications request the data sheet and verify under actual service conditions.
| Condition | Recommended material | Reasoning |
|---|---|---|
| 150 deg C continuous plus strong acid | PEEK / PVDF | Few materials satisfy both temperature and chemical resistance; PEEK adds strength, PVDF suits non-load-bearing corrosion-resistant parts |
| Gears, bearings and other sliding wear parts | POM / PA66 / UHMW-PE | Low friction and good wear resistance; POM offers better stiffness and dimensional stability, PA higher toughness but absorbs moisture |
| Food contact or medical equipment housings | PEEK / food-grade POM / PP | Requires an FDA or food-contact statement, with the grade, contact conditions and cleaning method confirmed |
| Electrical structural parts requiring UL94 V-0 | FR PC / PPS / PEEK | Flame retardance plus insulation plus dimensional stability; PC is more economical, PPS has better chemical and thermal resistance |
| High-precision fits where moisture growth is a risk | POM / PEEK / PC | Low moisture expansion; PA changes dimension noticeably after conditioning, so precision parts need care or moisture conditioning |
It depends on whether the part carries load. PEEK has far higher strength, stiffness and creep resistance, which suits structural and wear parts. PTFE offers extremely low friction and the widest chemical resistance, but low strength and high creep, so it suits seals, linings and insulation. When a part needs both load bearing and low friction, a common approach is a PEEK base with PTFE or graphite filler.
First confirm whether an FDA or EU 10/2011 compliance statement is required - this is a grade-level property, not a material-family property. Typical candidates are food-grade POM, PEEK, PP and PET. Also provide the contact media, contact temperature and cleaning method, because compliance statements are tied to those conditions.
Equilibrium moisture absorption for PA is typically 1.5 to 2.5 percent depending on grade and humidity, which can produce dimensional change of 0.3 to 0.6 percent - significant for fits tighter than IT7. For precision parts prefer POM (about 0.2 percent), PEEK or PC; if PA is required, moisture-condition the parts and dimension the drawing for the conditioned state.
Usually not. Flame retardants tend to reduce toughness and chemical resistance and add cost. However, if the part sits near a heat source or the end product certification demands that rating, follow the assembly-level requirement even when the part itself has no explicit one.
Typical values on standard specimens are usually the same, but the core of a thick sheet or large-diameter rod has different crystallinity and internal stress from the surface, so real load capacity is lower. For thick sections, test at the actual thickness or specify an annealed condition.
No. The output is a shortlist plus items to verify - a concept-stage narrowing tool. Before finalising you need to confirm the exact grade, stock shape and size, tolerances, colour, certification documents, and verification under actual conditions such as immersion, ageing and assembly testing.